| 00: Index of TDTS Notes September 2008 |
04 Sep 2008 |
43Kb |
 |
| 01: Uptake Rates for Tube Type, Axial Diffusive Samplers |
25 Jul 2006 |
404Kb |
 |
| 02: Prediction of Uptake Rates for Diffusive Tubes |
25 Jul 2006 |
315Kb |
 |
| 03: National and International Standard Methods Related to Speciated Monitoring of Vapour-phase Organic Chemicals in Air |
25 Jul 2006 |
381Kb |
 |
| 05: Advice on sorbent selection, tube conditioning tube storage and air sampling |
02 May 2008 |
93Kb |
 |
| 06: Problem Solving |
25 Jul 2006 |
317Kb |
 |
| 07: Calibration - Preparing and Introducing Thermal Desorption Standards using Sorbent Tubes |
25 Jul 2006 |
936Kb |
 |
| 08: Principles of Diffusive Monitoring |
25 Jul 2006 |
554Kb |
 |
| 09: Monitoring Materials and Processes for VOCs at High and Trace Levels |
25 Jul 2006 |
656Kb |
 |
| 10: Use of Diffusive Samplers with Thermal Desorption - Capillary GC Analysis for Monitoring Volatile Organic Compounds (VOCs) in Ambient Air |
25 Jul 2006 |
423Kb |
 |
| 11: Thermal Desorption - the Good, the Bad and the Ugly |
30 Jun 2005 |
105Kb |
 |
| 12: About thermal desorption - a basic introduction |
07 Feb 2008 |
485Kb |
 |
| 13: Evaluation of a new device for non-invasive biological monitoring of VOCs |
30 Jun 2005 |
210Kb |
 |
| 14: Analysis of labile, high-boiling organic vapours known to cause contamination issues when present in Semiconductor cleanroom fabrication facilities |
30 Jun 2005 |
624Kb |
 |
| 15: On-line process control of speciated organic chemicals in carbon dioxide and other industrial gases at sub-ppb levels |
30 Jun 2005 |
208Kb |
 |
| 16: Round the clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene ot trimethyl benzene in ambient air |
30 Jun 2005 |
337Kb |
 |
| 17: UNITY thermal desorber - GC-FID sensitivity |
30 Jun 2005 |
467Kb |
 |
| 18: Development in the determination of nitrous oxide using thermal desorption - GC |
30 Jun 2005 |
37Kb |
 |
| 19:Minimising artefacts - considerations for storage & transportation of sorbent tubes |
30 Jun 2005 |
111Kb |
 |
| 20. Confirming sorbent tube retention volumes and checking for analyte breakthrough |
28 Apr 2008 |
200Kb |
 |
| 21: Analytical thermal desorption: developing and optimising methods |
30 Jun 2005 |
40Kb |
 |
| 22: Selection of gas flows and split ratios during thermal desorption |
30 Jun 2005 |
37Kb |
 |
| 24: Using UNITY to recollect desorbed samples for repeat analysis |
04 Dec 2002 |
174Kb |
 |
| 25: Calculating atmospheric concentrations from analyte masses retained on sorbent tubes |
20 Jul 2005 |
71Kb |
 |
| 26: Minimising Analytical Interference from Water during the Analysis of Sorbent Tubes |
04 Dec 2002 |
33Kb |
 |
| 27: Sampling Methods for Monitoring VOCs in Air by Thermal Desorption -GC(-MS) |
25 Jul 2006 |
956Kb |
 |
| 28: Optimising Analytical Performance and Extending the Application Range of Thermal Desorption for Monitoring Air Indoors and Inside Vehicle Cabins |
28 Feb 2003 |
246Kb |
 |
| 29: VOC Air Monitoring Technology and its Application to Contaminated Land |
04 Mar 2003 |
272Kb |
 |
| 30 Certified Reference Materials for Analysis of VOCs in Air by Thermal Desorption (TD) - GC |
03 Aug 2004 |
483Kb |
 |
| 32: The analysis of sulphur compounds using on-line and off-line thermal desorption - GC(MS) |
24 Aug 2007 |
1213Kb |
 |
| 33: ANALYSIS OF THE INTERIOR ATMOSPHERE OF A SALOON CAR USING THERMAL DESORPTION AND GCMS |
27 Jan 2003 |
363Kb |
 |
| 34: MONITORING TRACE LEVEL HIGH-BOILING COMPOUNDS IN AIR |
27 Jan 2003 |
87Kb |
 |
| 35: THERMAL DESORPTION OF DIOCTYL PHTHALATE AND OTHER PLASTICIZERS. |
29 Jan 2003 |
90Kb |
 |
| 36: The application of automated mass spectral deconvolution (AMDIS) using a TD GCMS method, for the analysis of target chemical warfare agents in air |
16 Oct 2006 |
839Kb |
 |
| 37: Workplace air monitoring using pumped sampling onto sorbent tubes and thermal desorption |
19 Oct 2007 |
1164Kb |
 |
| 38 Low Occupational Exposure Limit Levels Favouring Analysis by Thermal Desorption - GC(-MS) |
19 Oct 2007 |
133Kb |
 |
| 39 Analysis of semi-volatile phosphorus pesticides using MiT thermal desorption systems - Demonstration of method validation using SecureTDT |
24 Sep 2003 |
132Kb |
 |
| 40: DIRECT DESORPTION OF VOLATILE AND SEMI-VOLATILE ORGANIC COMPOUNDS FROM FURNISHINGS SUCH AS LEATHER OR TEXTILES |
29 Jan 2003 |
159Kb |
 |
| 41: Analysis of the Residual Solvent Dimethyl sulfoxide in a Drug Precursor |
29 Jan 2003 |
86Kb |
 |
| 42: Uptake Rates for Radial Diffusive Samplers |
04 Mar 2003 |
31Kb |
 |
| 43: Large-scale monitoring of mono ethylene glycol (MEG) vapour in natural gas using pumped sampling onto Tenax tubes followed by thermal desorption - capillary GC analysis |
28 Feb 2003 |
99Kb |
 |
| 44 THEANALYSIS OF FREE-VX FROM SORBENT TUBES AT LOW AND SUB NANOGRAM LEVELS |
08 Sep 2003 |
195Kb |
 |
| 45 Trace detection of proscribed drugs by UNITY TD-GC-MS |
23 Aug 2004 |
60Kb |
 |
| 46: Comparing thermal desorption with carbon disulphide extraction of charcoal for air monitoring methods |
19 Oct 2007 |
393Kb |
 |
| 47 The Analysis of Landfill Gas Compounds using Thermal Desorption GCMS and a Retention Time Locked Database |
21 May 2004 |
1344Kb |
 |
| 49Fence-line and ambient monitoring of benzene and other hydrocarbons using diffusive sampling and thermal desorption analysis |
15 Oct 2004 |
1728Kb |
 |
| 51: Characterisation of a Natural Product using SensorTiveT Technology |
29 Jan 2003 |
220Kb |
 |
| 52 The use of Thermal Desorption-GC(-MS) in flavour and fragrance profiling and food / consumer product analysis |
03 Sep 2004 |
760Kb |
 |
| 53: Quantitative Recovery of High Boiling (> 450°C) Semi-Volatiles (sVOCs) using Thermal Desorption - GC- MS |
02 Jun 2008 |
120Kb |
 |
| 55 Using the FLEC Cell to Determine Volatile Organic Emissions from Indoor Materials and Products |
11 Aug 2005 |
202Kb |
 |
| 56: TD-GC-MS analysis of VOCs for materials emissions testing |
30 Jun 2005 |
164Kb |
 |
| 57 Characterisation of paint samples by direct desorption |
15 Nov 2004 |
192Kb |
 |
| 58. The Application of Thermal Desorption to Forensic Investigations |
24 Jul 2006 |
675Kb |
 |
| 59 Direct desorption of Car Trim Materials for Volatile Organic Compounds (VOC) and Semi-volatile Organic Compounds (SVOC) analysis. In accordance with method VDA 278. |
23 Aug 2004 |
568Kb |
 |
| 60 The complementary role of thermal desorption (TD) alongside other sample preparation / introduction technologies for Gas Chromatography (GC) |
22 May 2007 |
38Kb |
 |
| 61 Diffusion Locking Technology |
21 May 2004 |
774Kb |
 |
| 62 Materials emissions testing in the semiconductor and associated industries |
11 Aug 2005 |
732Kb |
 |
| 63: Using the TT24-7 with twin electrically-cooled focusing traps for continuous monitoring of trace level toxic chemicals (e.g. Chemical Warfare Agents) in air |
30 Jun 2005 |
977Kb |
 |
| 64: Simultaneous TD-GC(-MS) analysis of VOCs and Semi-VOCs |
23 May 2008 |
130Kb |
 |
| 65: Automating the measurement of VOCs and semi-VOCs in building materials and car trim components using direct thermal desorption |
01 Jul 2005 |
1044Kb |
 |
| 66: Improving the identification and measurement of trace odorous and toxic components during materials emissions testing |
30 Jun 2005 |
978Kb |
 |
| 67: Using the Micro-Chamber / Thermal Extractor (µ-CTE) to automate materials emissions testing for industrial quality control |
30 Jun 2005 |
754Kb |
 |
| 69: The Micro-Chamber / Thermal Extractor - the Innovative, Rapid and Cost Effective Approach for Testing VOC Emissions from Materials |
25 Jul 2006 |
300Kb |
 |
| 70 Materials emissions testing using the FLEC Cell Testing recovery and sink effects |
25 Apr 2003 |
81Kb |
 |
| 71 Summary of FLEC Applications |
28 Apr 2003 |
73Kb |
 |
| 72 An Introduction to Emission Cells and Comparison to Small Chambers for Materials Emissions Testing |
14 Oct 2004 |
176Kb |
 |
| 73: Summary of peer-reviewed publication: ‘A microscale device for measuring emissions from materials for indoor use’ |
22 Apr 2008 |
375Kb |
 |
| 74: Summary of peer-reviewed publication: ‘Emission cells and comparison to small chambers for materials emissions testing’ (Source: www.gefahrstoffe.de) |
19 May 2008 |
1784Kb |
 |
| 75: Liquid Standard Injection, Tube Impedance and Other Factors which may Cause Discrimination during the Calibration of Thermal Desorption Methods |
02 May 2008 |
316Kb |
 |
| 77: Using Thermal Desorption for Industrial (Stack) Emission Testing |
24 Jul 2006 |
429Kb |
 |
| 78. Low ppt levels of geosmin, methyl-i-borneol and other odorants in drinking water using headspace – thermal desorption (HS-TD) |
11 Sep 2007 |
1601Kb |
 |
| 78b: Supplement to TDTS 78 - Low ppt levels of odorants in drinking water using headspace – thermal desorption (HS-TD) |
11 Sep 2007 |
585Kb |
 |
| 79: Air monitoring - the respective advantages and applications of canisters and tubes |
19 Mar 2008 |
114Kb |
 |
| 80: Evaluation of a ‘Soil Gas’ sorbent tube for improving the measurement of volatile and semi-volatile fuel vapors in soil contaminated land |
17 Mar 2008 |
514Kb |
 |
| 81: Analysis of canister air samples using cryogenfree thermal desorption in compliance with US EPA method TO-15 |
21 Oct 2008 |
893Kb |
 |
| 82: TubeTAG - Enhanced tracking of sample- and tube-related information for thermal desorption |
27 Mar 2008 |
194Kb |
 |
| 83: Enhancing TD-GCMS methods for trace compound analysis using ClearView™ reprocessing software |
21 Oct 2008 |
597Kb |
 |
| 84: Using thermal desorption to enhance aroma profiling by GCMS – featuring example applications from the tobacco industry |
17 Jun 2008 |
468Kb |
 |
| 85: GCMS data analysis using ClearView™ reprocessing software: Dealing with common ions |
16 May 2008 |
476Kb |
 |
| 86: EPA Method TO-17 for monitoring ‘air toxics’ in ambient air using sorbent tubes and automated, cryogen-free thermal desorption |
21 Oct 2008 |
1381Kb |
 |
| Application Enquiry Form |
01 Jul 2005 |
52Kb |
 |
| Application Enquiry Form (German) |
30 Jun 2005 |
52Kb |
 |
| Applications Enquiry Form (French) |
30 Jun 2005 |
52Kb |
 |
| Paper: Enhanced GC-MS aroma profiling using thermal desorption technologies (Separation Science, September 2008) |
11 Sep 2008 |
3656Kb |
 |
| Paper: Enhancing GCMS analysis of trace compounds using a dynamic approach to reducing background interference (The Column, July 2008) |
11 Sep 2008 |
1801Kb |
 |
| Paper: Evaluation of a new Dynamic Background Compensation Algorithm for Improving Aroma Characterisation by Thermal Desorption – GC-MS (Chromatography Today, October 2008) |
20 Oct 2008 |
608Kb |
 |